ST-630E Stand-Alone Access Control
Operation Manual
Ⅰ Features
z
z
z
z
z
Master Card and Codes
Auto Reset Function
Security System Setting/ Release
Synchronize with Security System
Entering/Exiting Programming Mode: Only Proximity
Codes + Proximity, Codes or Proximity
Door Status Monitor Function
z
z
z
Anti Pass Back Function
Emergent Access Alarm, Time Delay Alarm and Forced
Door Alarm output
z
z
z
Dual relays programmable On/Off or pulsed or latched mode
LED Indicator to distinguish the status
Use for all kinds of the electric lock.
Ⅱ. The Specifications:
Part No.
ST-630E
Connection
/Users
Connection/ Stand-alone
1000
/Record Volumes
Reader Application
Keys
1000
WG26,WG34
12 Keys (0-9,*,#)
Interface
RS485
Proximity Distance
Proximity
About 125 and 15 cm/13.56 for around 7 cm
125Khz (EM)
Frequency
Indicators
3 LEDs
Dimension (mm)
114(L) x 69.5(W) x 10(D)mm
12 VDC
-5 C-60 C
Operating Voltage:
Temperature
5%-95%(Non-condensing)
Humidity
Copyright All Rights Reserved.
Page 1 of 5
P-MU-ST-630 Ver. A Publish: 2009.01.08
Ⅳ Operation Instruction:
Enter Program Mode,Enter 6-digital Codes,(Default 123456)
*xxxxxx#
*
#
Exit Program Mode
01*xxxxxx xxxxxx #
02*xxxx #
Change Default Password, Press twice new 6-digital Codes
Controller Station Setting[001-254]
Access only with the password, 0000-Unavaliable (Default, 0000)
05*xxx#
10*xxxx*XXXXXXXXXX # Adding or Revised the Cards No.
Slot Position =00001~01000 and enter the 10 digital Cards No.
12*XXXX*XXXXX#
Adding the batch series Cards No.. XXXX=the beginning position
*XXXXX=the quantities of the batch series card No.
(The access mode is for Card Only)
Modify the cards access parameter
xxxxx= The beginning slot position
XXXXX= the ending slot position
(ps. x≦01000)
13*xxxxx*XXXXX*N #
From=00001~01000
N is 0= Access not allow,1=Card only, 2=Cards or Code,
3=Card & Code, 4= Clear card information
(When modify the Mode to “Card or Code” or “ Card & Code”,the
default Code is 0000.
Set the position of the Code; xxxxx=slot position XXXX=4-digital
Code (Position =00001~01000)
14*xxxxx*XXXX#
15*99#
Clear all Cards (Not including Master Cards)
When forget the Cards slot position,can clear the cards information
by enter Cards No..
17*xxxxxxxxxx#
21*xxx#
22*xxx#
Alarm Time Delay Setting xxx=000~255 Seconds
Dual relays programmable time delay xxx=000~250 Seconds
(External Relay for Security System)
(000 Latched Operation) (Default is 15 Seconds)
Master Cards Setting x=(1 or 2). 2 Master Card available
In the normal status, proximity the Master cards to Program Mode.
Security Cards arrange Setting XXXXX=00001~01000 .The arrange
of the No. should be continuing which can’t skip the No.
x=0 General Setting Mode (Default x=0)
25*X#
26*xxxxx*XXXXX#
30*x#
x=1 Card Only. Access the door by reading cards that no matter the
cards are set into the system or not.
Anti Pass Back Function
32*x#
x=0/ OFF
X=1/ ON
33*x#
Two Doors Synchronize x=0 OFF X=1 ON,Access
Copyright All Rights Reserved.
Page 3 of 5
P-MU-ST-630 Ver. A Publish: 2009.01.08
Controller and Reader can open different doors.
34*99#
Reset the function of Anti Pass Back.
x=1= access record to duty
35*x# (for connecting
controller)
x=0= access record Not to Duty
(x= default is 0)
38*x#
x=0 Green LED is controlled by Controller x=1 Green LED is
controlled by external system
(The second Relay contact to the Door Status and negatron (-) ,
Green LED flash can synchronize with Security System.
Reset to Default, and clean the controller memory to the factory
default
51*99#
55*99#
Add New Cards,read card once and 1 Beep heard for adding the
new card. Read card twice and 2 Beep heard to delete the cards.
(After add Cards,the default access mode is “Card Only”)
70*X# [For LCD series]X=0 Screen Backlight ON ,x=1 Screen Backlight Off automatically
Emergent Code Setting,Enter twice 6-Digital Code。
Enter the Code can link to the other relay to activate the external
system. 22*xxx # for setting the active time. (second)
xxx=000~255 Seconds
71*XXXXXX XXXXXX #
72*xxx#
73*x #
Door Left Open Alarm Time Delay - The door does not close after the
limited time, and the controller will output the alarm.
x=1 Enter the emergent code or press 99* with Security Cards, the
relay of the controller/ ON; X=0 OFF
74*x#
76*x#
99*
X=1 Door Left Open Alarm and Force Open Mode are ON; X=0 OFF
X=1 Emergent Alarm /ON,x=0 OFF
When setting or Release the External Relay, Please enter the
codes99*and then read the security card.
(Operating in the Normal Mode.)
Ⅴ、 Wiring diagram:
Copyright All Rights Reserved.
Page 4 of 5
P-MU-ST-630 Ver. A Publish: 2009.01.08
Copyright All Rights Reserved.
Page 5 of 5
P-MU-ST-630 Ver. A Publish: 2009.01.08
|
Eizo Computer Monitor L665 User Manual
Extron electronic Car Amplifier MPA 401 70V User Manual
Festool Saw KS 120 User Manual
Fisher Price Baby Toy V3400 User Manual
Fisher Price Fitness Equipment C4492 User Manual
Fisher Price Motorized Toy Car C2390 User Manual
Fostex Microphone SF20C User Manual
Geemarc Telephone TP38 User Manual
Gefen Portable Generator GTB HD SIGGEN User Manual
Gigabyte Network Router RS16000 User Manual